Skip to main content
IP66, IP67 and IK10: what do those codes say about your security camera?
Guides - 25 November 2026 · 6 min read

IP66, IP67 and IK10: what do those codes say about your security camera?

IP66 means dust-tight and resistant to powerful water jets. IP67 means dust-tight and resistant to temporary immersion up to one metre. IK10 means the housing withstands a blow of 20 joules. For an ordinary outside wall, IP66 and IP67 are both fine. You mainly need IK10 if somebody can reach the camera.

IP66, IP67 and IK10: what do those codes say about your security camera?
In this article
  • What do the two digits after IP mean?
  • Is IP67 better than IP66?
  • What does an IP code not tell you?
  • What does IK10 mean?
  • Why does one camera have IK10 and another does not?
  • Which code do you need where?
  • Why can an IP67 camera still fill with water?
At a glance

In short

IP67 is not a higher grade of IP66: above 6 the water digits no longer add up automatically.
IK10 stands for 20 joules, comparable to a 5 kilo weight falling 40 centimetres.
The IP standard explicitly leaves rust, sunlight, ice, vermin and condensation to other product standards.

What do the two digits after IP mean?

The IP code comes from IEC 60529 and is about the housing. The first digit covers solids, from sand to a finger. A 6 is the highest: dust-tight. Almost every serious outdoor camera has that 6, so there is no need to choose on it.

The second digit is water. A 4 is splashing, a 5 an ordinary water jet, a 6 a powerful jet from a 12.5 millimetre nozzle. With a 7 the device goes under water for half an hour, up to one metre deep. With an 8 the manufacturer sets a more severe test and has to state it.

If you see an X, as in IPX7, that part was not specified. That is different from a zero.

Is IP67 better than IP66?

Not necessarily. A jet pushes water with force against one seam. Immersion presses gently and for a long time everywhere. A housing that passes one test does not have to pass the other. Up to and including 6 the lower digits are covered, above that they no longer are.

If a manufacturer wants to demonstrate both, the datasheet lists both, for instance IP66/IP67. If you only see IP67 and the camera hangs under a leaking gutter or at a wash area where a pressure washer is used, ask whether the jet test was done as well.

For rain on a wall it makes little difference. A camera there is not under water and does not face a fire hose either. Do not let anybody talk you into a more expensive model for that one digit.

What does an IP code not tell you?

The standard lists it itself. Protection against mechanical impacts, corrosion, corrosive liquids, fungus, vermin, solar radiation, ice and moisture from condensation is outside the test and is a matter for the product standard of the device.

That explains many complaints. A spider web in front of the lens, a discoloured cover or a misted dome after a cold night do not prove that the IP rating is wrong. They are things that were never tested.

The test is also done with a new device, fully assembled. A rubber seal that sits crooked after the housing was opened no longer meets the rating. So only open a camera if you have to, and never in the rain.

What does IK10 mean?

IK comes from IEC 62262 and expresses a blow in joules. IK08 is 5 joules, IK09 is 10 and IK10 is 20 joules. Those 20 joules correspond to a 5 kilo weight falling from 40 centimetres. Since an amendment in 2021 the scale continues to IK11, which stands for 50 joules.

A stone from the street or a blow with a stick is in that order of magnitude, a well-aimed hit with a sledgehammer is not. IK10 buys time and stops mischief. It does not make a camera indestructible.

The standard looks at whether the equipment inside stays protected. It does not say that the camera still looks in the same direction after the blow. A bullet on an arm can stay in one piece and still point at the ground.

Why does one camera have IK10 and another does not?

The shape counts. A flat dome has few protruding parts and a cover that can spread a blow. Hikvision, for example, lists IP67 and IK10 for a fixed 4 MP dome, while the sheet of an 8 MP turret from the same maker only shows IP67.

Watch the small print. With some Dahua models it literally says IK10 with the word optional in brackets. Then you have to order the exact part number that goes with that version. So ask for the datasheet of the exact model and do not go by the series name.

Which code do you need where?

Under an overhang or canopy: IP66 or IP67, IK does not matter. Exposed on a wall above three metres: the same. Low down at a back entrance, gallery or porch: IP66 or IP67 with IK10, and preferably a dome. In a car park or a school yard I would make IK10 a requirement.

A stable, car wash or kitchen asks for more than a digit. Ammonia, soap and grease play a part there, and IP says nothing about them. By the sea you look at corrosion protection. Hikvision distinguishes levels for this and names the coast as the place for the heaviest class, with a middle class for areas about two kilometres from the sea.

Finally, look at the temperature range. It is separate from both codes and, for a camera on a black painted south wall, often matters more than the difference between a 6 and a 7.

Why can an IP67 camera still fill with water?

Because the water usually does not come through the camera but along the cable. The code applies to the housing, not to a plug lying loose in a gutter or to the hole in your wall. An open RJ45 coupling draws in moisture and that creeps further along the cable.

So with a quotation, do not only ask about the IP rating of the camera. Also ask where the connector goes, which box is behind it and how the wall entry is finished. A junction box with a lower digit than the camera makes the whole connection only as good as that box.

Frequently asked questions

Is IP65 enough for an outdoor camera?

Under an overhang it usually is. IP65 is dust-tight and resistant to an ordinary water jet. If the camera hangs exposed to the wind or you clean the wall with a pressure washer, choose IP66.

Can I spray my camera with a pressure washer?

Better not. Even IP66 is tested with a fixed jet at a distance, not with a lance a few centimetres away. A soft cloth with lukewarm water is enough and spares the seal and the coating on the glass.

What is IP69K on a camera?

It is a test with hot water under high pressure from close by, meant for vehicles and steam cleaning among other things. You come across it in the food industry. You do not need it for a home or office.

Does the IP rating also apply to the bracket and mounting box?

No, they have their own rating or none at all. Check the datasheet of the box separately, especially if the power or network plug will sit inside it.

Does IK10 also protect against scratches or paint on the dome?

No. The IK test measures a blow. A scratch, a sticker or a spray can make the picture useless while the housing stays intact. Set an alert for a covered lens if your camera can do that.

Sources

What this information is based on

IEC 60529 (preview)Scope of the IP code and what falls outside it.View the start of IEC 60529
IEC 62262 (preview)The IK code including the 2021 amendment.View the start of IEC 62262
RS on IP ratingsMeaning per digit and why 7 and 8 do not add up.Read the RS explanation
Interelectronix on EN 62262Joules per IK code with weight and drop height.View the IK table